  Thermal Performance Data  
     
  Window Type Clear Glass LoE Glass LoE/Argon Gas  
Clear w/Grilles Clear w/Grilles Clear w/Grilles
6000 AWN 0.45 0.45 0.34 0.34 0.31 0.31
9100/7100/5100 FL 0.49 0.49 0.34 0.34 0.30 0.30
7000 CW 0.45 0.45 0.34 0.34 0.31 0.31
9000 DH 0.50 0.50 0.37 0.37 0.33 0.33
5000 SL 0.49 0.49 0.36 0.36 0.32 0.32
     
Structural Performance Data
 
Window Type Test Method Window Size Air Infiltration @ 25 MPH Water Penetration (PSF) Structural Performance (PSF) Rating
  9100/7100/5100 FL AAMA/NWWDA 101/IS.2 60"x72" 0.07 CFM 7.5 75 F-C50  
  7000 CW AAMA 101-93 56"x64" 0.05 CFM 8.25 52.5 C-R35  
  9000 DH AAMA/NWWDA 101/IS.2 44"x60" 0.1 CFM 6.75 67.5 DH-R45  
  5000 SL AAMA/NWWDA 101/IS.2 72"x48" 0.08 CFM 6 52.5 HS-R35  
     
Picture Window Thermal and Structural Ratings  
   
Structural Performance Thermal Performance  
Test Method Rating Glass Type Tested to NFRC 100-97
  AAMA/NWWDA 101/IS.2-97 F-C50 7/8" Clear U Value = 0.59  
7/8" LoE U Value = 0.43
7/8" LoE Argon U Value = 0.39
       
  Double Hung Window Thermal and Structural Ratings  
     
Structural Performance Thermal Performance  
Test Method Rating Glass Type Tested to NFRC 100-97
AAMA/NWWDA 101/IS.2-97 DH-C50 7/8" Clear U Value = 0.64
7/8" LoE U Value = 0.50
  7/8" LoE Argon U Value = 0.46
         
 
 
 